Skip to table
Design Calculations · DIN 509 undercut table

DIN 509 undercut table (type E and F)

Common sizes for type E and F, in millimetres

This DIN 509 undercut table lists the dimensions for type E and F: radius r, depth in cylinder t1, depth in shoulder t2, width along axis f, width on shoulder g and the minimum countersink a on the mating part. All values are in millimetres. Series 1 is preferred.

DIN 509 undercut calculator

Calculate the undercut for your shaft diameter

Swipe the table sideways to see all columns.

DIN 509 undercut sizes, series 1 (preferred), type E and F (7 rows). All dimensions in mm.
d1 (mm) Load Series Undercut dimensions (mm) a min. (mm)
r t1 t2type F f gtype F, guide value Type E Type F
Ø > 3 to 18Normal load1*0.40.20.121.10.30
Ø > 18 to 80Normal load1*0.80.30.22.52.30.60.05
Ø > 80Normal load1*1.20.40.343.40.90.1
Ø > 18 to 50Higher alternating load1*1.20.20.12.521.10.6
Ø > 50 to 80Higher alternating load1*1.60.30.243.11.40.6
Ø > 80 to 125Higher alternating load1*2.50.40.354.82.21
Ø > 125Higher alternating load1*40.50.376.43.62.1

This is a selection of common sizes: series 1 (preferred). For every size in the standard, including series 2, use the DIN 509 undercut calculator.

Tolerances: r ± 0.1; t1 +0.1 / 0; t2 +0.05 / 0; f +0.2 / 0. g is a guide value (type F only). t2 applies to type F only. a = 0: no minimum. * Series 1 is preferred.

Higher alternating load: the load keeps changing. The standard gives sizes for this above Ø 18 mm.

Diameter ranges are over the lower value, up to and including the upper value. For Ø 1.6 mm and smaller DIN 509 gives no undercut size. Above Ø 500 mm: outside the usual range; check the size against the standard.

The split by diameter does not apply to short shoulders and thin-walled parts. If a part has several diameters, you may use the same undercut at all shoulders.

Source: DIN EN ISO 18388 (ISO 18388:2016); the same table appeared in DIN 509:2006-12. The tolerances come from DIN 509:2006-12. The newer DIN 509:2022-12 sets them again; that text has not been checked. Tolerances from DIN 509:2022 not confirmed.

DIN 509 undercut calculator

Calculate the undercut for your shaft diameter

The dimensions come from the standard and are meant as an aid. Always check your own drawing and the current standard. You remain responsible for your design.