Thickness, inside radius and angle → K-factor, bend deduction and flat length
| Difference in flat length |
|---|
Inventor: Sheet Metal Defaults › Edit Unfold Rule › Linear › KFactor Value
Guide values for air bending. The row and column of your input are highlighted. With bottoming or coining K is higher, for steel about 0.44–0.47.
| Material | r/t ≤ 1 | 1 < r/t ≤ 3 | r/t > 3 |
|---|---|---|---|
| Steel (S235, DC01) | 0.38 | 0.43 | 0.50 |
| Stainless (304, 316) | 0.40 | 0.45 | 0.50 |
| Aluminium | 0.33 | 0.40 | 0.50 |
| Copper / brass* | 0.33 | 0.40 | 0.50 |
* Copper / brass: assumption, soft-material values (same as aluminium).
The results are guide values. The real K-factor depends on the press brake, the tooling, the grain direction and the material batch. Always do a test bend for critical dimensions. You remain responsible for your design and the calculation.
DIN 6935 was written for steel; for aluminium and copper the formula is an approximation. The K-factor tells where the neutral line lies: at K × t from the inside. That line keeps its length while bending.
BA = π × A / 180 × (r + K × t)
OSSB = (r + t) × tan(A / 2) · BD = 2 × OSSB − BA
Flat length = L1 + L2 − BD
DIN 6935: k = 0.65 + 0.5 × log₁₀(r / t), k ≤ 1 → K = k / 2
DIN 6935 puts the neutral line at k × t / 2; so the K-factor here is half the DIN value k. For r/t ≥ 5, K = 0.5 (middle of the sheet).
Working back: BD = L1 + L2 − measured flat, BA = 2 × OSSB − BD, K = (BA × 180 / (π × A) − r) / t.
In Inventor the K-factor sits in the unfold rule: Sheet Metal Defaults → Edit Unfold Rule, Unfold Method = Linear, KFactor Value (default 0.44). The sheet metal rule itself has no Unfold tab. For a different value per thickness, use a bend table or one rule per thickness.
Three cases you can check with the formulas. The button puts the same input into the tool.
r/t = 1 → table K = 0.38. BA = π/2 × (2 + 0.38 × 2) = 4.335 mm; OSSB = 4 mm; BD = 3.665 mm. Flanges 50 and 30 → flat 76.34 mm.
r/t = 2 → k = 0.65 + 0.5 × log₁₀ 2 = 0.801 → K = 0.400. BA = π/2 × (6 + 1.2) = 11.31 mm; OSSB = 9 mm; BD = 6.69 mm. Flanges 40 and 40 → flat 73.31 mm.
r 1.5, 90°, flanges 50 and 50, measured flat 97.2 mm → BD = 2.8 mm, BA = 3.2 mm → K = 0.358.
The experience value for 3 mm stainless steel in air bending with a V24 die and an inside radius of about 5 mm (r/t ≈ 1.7) is K ≈ 0.40, with a range of 0.39–0.41. The rule-of-thumb table gives a coarser 0.45 for stainless at 1 < r/t ≤ 3, so the experience value is lower. If your press brake shop uses another die, K changes with it: enter the value from your shop.
For air bending the table gives 0.38 for steel (S235, DC01) at r/t ≤ 1, 0.43 at 1 < r/t ≤ 3 and 0.50 at r/t > 3. For aluminium that is 0.33, 0.40 and 0.50. With bottoming or coining K is higher, for steel about 0.44–0.47.
Flat = L1 + L2 − bend deduction (BD). Example: steel 2 mm, inside radius 2 mm, 90°, K = 0.38. Then BA = π/2 × (2 + 0.38 × 2) = 4.335 mm, OSSB = 4 mm and BD = 2 × 4 − 4.335 = 3.665 mm. With flanges of 50 and 30 mm the flat length is 76.34 mm.
Measure the flat length of a test strip and the outside dimensions of the bent part: BD = L1 + L2 − flat. Example: stainless 1.5 mm, r = 1.5 mm, 90°, flanges 50 and 50 mm, measured flat 97.2 mm. Then BD = 2.8 mm, BA = 2 × 3 − 2.8 = 3.2 mm and K = 0.358.
The Linear K-factor in the unfold rule (Sheet Metal Defaults › Edit Unfold Rule › Unfold Method Linear › KFactor Value) defaults to 0.44. For 3 mm stainless steel with a V24 die (r ≈ 5 mm, 90°), K = 0.44 instead of K = 0.40 changes the bend allowance by about 0.19 mm per bend. The Flange Angle in Inventor is the bend angle A (0° = flat): choose “Bend angle A” here. Default in the Inventor template: 0.44.
The figures come from the table, the examples and the experience value above. Always do a test bend for critical dimensions.