Design Calculations · ISO 286 fit calculator

ISO 286 fit calculator

Nominal size, hole class and shaft class → limit dimensions, clearance or interference, and designations to copy

mm
Hole and shaft have the same nominal size: over 1 up to and including 500 mm.
Common fits

Fills in the hole and shaft class. The size stays.

Hole (internal feature)
Shaft (external feature)
Letter and grade together make the class, for example H7 or g6. Capital letters are for the hole, small letters for the shaft.
Diameter symbol in copied designations
Ø 20 H7/g6 or 20 H7/g6. The numbers themselves are the same.
—

Limit deviations: ISO 286-1 and ISO 286-2, compiled from public tables.

About the values

The limit deviations follow from the fundamental deviation (the letter) and the tolerance grade (the number) at the size range your nominal size falls in. Fit = hole − shaft: smallest = lower limit of the hole − upper limit of the shaft, largest = upper limit of the hole − lower limit of the shaft. Temperature, surface roughness, form errors and coatings are not included.

Inventor: Manage › Parameters, or straight into the dimension and tolerance fields of your sketch. Copied numbers always use a decimal point.

Tolerance zones against the nominal size (not to scale between sizes)
Enter the nominal size: the limits and the fit appear here.

The values are an aid, compiled from public ISO 286 tables. Check them against the standard and against your own drawing. You remain responsible for your design.

Details: explanation, Inventor and sources

How to read this

Class. A class is a letter and a number. Capital letters are for holes (H7), small letters for shafts (g6). The letter says where the tolerance zone lies against the nominal size (H and h: on the nominal size, the others above or below it). The number is the tolerance grade: the higher, the wider the zone.

Fit. Fit = hole − shaft. The smallest fit is the lower limit of the hole minus the upper limit of the shaft, the largest fit is the upper limit of the hole minus the lower limit of the shaft. If the smallest fit is 0 or more, it is a clearance fit. If the largest is 0 or less, it is an interference fit. Anything in between is a transition fit. A minus sign means interference.

Any pair. You can combine any hole class with any shaft class, also pairs that are not standard (for example C11 with h7). The page does not judge whether that is a sensible fit.

Not covered. Sizes outside 1 to 500 mm, grades below IT5 or above IT16, the letters cd, ef and fg, and classes that ISO 286 does not define at the chosen size. Shaft j exists in IT5 to IT7 and hole J in IT6 to IT8. Hole K above IT8 exists up to 3 mm only.

How to use it in Inventor

  1. For a drawing the class is often enough: copy the designation (for example Ø 20 H7) and use it in the dimension text, or choose the same class in the tolerance settings of the dimension.
  2. If you need the numbers, copy the upper and lower deviation. They use a decimal point, as Inventor expects.
  3. Put the diameters in parameters, so one change updates hole, shaft and the fit.

Sources

  • ISO 286-1 and ISO 286-2, limits and fits. The standard text is not public. The numbers are compiled from several public reference tables and compared with each other: the fundamental deviations of the shafts from three tables, the tolerance grades from three tables, and every class again against per-class tables from two other pages. Where one table differed from the others, the standard's own rules and the majority of the tables decided.
  • The hole values follow from the shaft values with the rules of ISO 286-1 (general rule for A to H, special rule with delta for K, M, N up to IT8 and P to ZC up to IT7).