Design Calculations · Keyway DIN 6885

Keyway (DIN 6885-1, form A)

Shaft diameter → key b × h, groove depths t1 and t2, groove width limits (P9, N9, JS9)

mm
Nominal shaft diameter, over 6 up to 500 mm. At 8 mm you get the 2 × 2 key, at 8.1 mm the 3 × 3.
Common diameters

Fills in the diameter only.

Fit of the key in the grooves
Normal: N9 in the shaft, JS9 in the hub; easy to assemble. Tight: P9 in both; for hubs that must stay fixed, also with reversing or shock loads.
Standard lengths for the key of this diameter; the list follows the diameter. Choose one to add the length to the designation and to get the groove length.
—

A minus sign on the fit means interference: the key is larger than the groove.

Source: DIN 6885-1 (high form, form A); limits per ISO 286.

About the values

b × h, t1 and t2 follow DIN 6885-1. The tolerance of t1 and t2, the check dimensions and the width limits are taken from public tables and from ISO 286, not from the standard text itself. For critical parts, check them against your copy of the standard. The same goes for the standard key lengths, the length range per key width and the tolerances h14 and H15 (h14 from ISO 286 grade IT14; H15 per ISO R773 / GOST 23360, from ISO 286 grade IT15): for key widths from 40 mm up, public tables differ on the length range.

Inventor: Manage › Parameters, or straight into the dimension and tolerance fields of your sketch. Copied numbers always use a decimal point.

Cross-section of a shaft with a key in a groove: key width b, key height h, groove depth t1 in the shaft, groove depth t2 in the hub and shaft diameter d. bht1t2 hubshaftkey
Cross-section: shaft, key and hub
Enter a diameter: the dimensions appear here.

The dimensions come from the standard and are meant as an aid. Always check your own drawing and the current standard. You remain responsible for your design.

Details: explanation, Inventor and sources

What is a keyway?

A parallel key (DIN 6885-1, form A, high form with round ends) carries torque between a shaft and a hub such as a gear, pulley or coupling. The shaft diameter decides the key width b and the key height h. The groove in the shaft is t1 deep, the groove in the hub t2 deep.

Fit. The width of the grooves decides how the key sits. Tight: P9 in the shaft and in the hub, for hubs that must stay fixed. Normal: N9 in the shaft and JS9 in the hub, easier to assemble. The key itself is h9. The sliding fit (H9 in the shaft, D10 in the hub) is not on this page.

Check dimensions. t1 is hard to measure on a finished shaft. So the drawing also gives d − t1 (from the opposite side of the shaft to the groove bottom) and, for the hub, d + t2. Here they are derived from t1 and t2: the same tolerance, in the other direction for the shaft.

The page gives one key per diameter, as the standard does. You can also choose the key length l from the standard lengths: the page then gives the key length (h14) and the groove length in the shaft (H15), and adds the length to the designation.

How to use it in Inventor

  1. Sketch the cross-section of the groove on the end face of the shaft or on a plane through the shaft axis, and cut it with Extrude.
  2. Click a dimension and copy the nominal value from this page. In the tolerance settings of that dimension, paste the upper and lower deviation (they use a decimal point, as Inventor expects).
  3. Put b, t1 and t2 in parameters, so one change updates all grooves.
  4. On the drawing, give b with its class (N9, P9 or JS9) and d − t1 or d + t2 as the check dimension.

Sources

  • DIN 6885-1:2021-11, Drive type fastenings without taper action – Parallel keys, keyways – High form (form A). b × h, t1 and t2: checked against three public copies of the table; the standard text itself was not read.
  • ISO 286-1 and ISO 286-2, limits and fits: the width limits for P9, N9, JS9 and for the key (h9) are calculated from the tolerance grade IT9 and the fundamental deviations, and checked against a public key table.
  • Tolerance of t1 and t2: +0.1/0 for key widths 2–6, +0.2/0 for 8–32 and +0.3/0 for 36–100 (public manufacturer table). One public catalogue excerpt shows +0.1 for t2 at d = 24 mm; that looks like a printing difference.
  • Key length: the standard lengths and the length range per key width come from public tables (including older DIN 6885-1 and ISO R773 / GOST 23360); for key widths of 40 mm and up, public tables differ on the minimum and maximum length. This page uses the lower minima those sources agree on; the maximum stays at 400 mm. The standard itself was not read. h14 (key length) is calculated from IT14 of ISO 286-1; H15 (groove length) per ISO R773 / GOST 23360, from IT15 of ISO 286-1, checked against two public copies of that table.